Fast Ethernet
100 Mbps lato rame e 100Mbps lato fibra |
Modelli Gestiti |
Modelli Non Gestiti |
Descrizione |
Con. |
|
|
- Distanze fino a 120 km
- Per Fibra multimodo o monomodo; Connettori SC, LC e ST
- Funzioni avanzate - Link Pass-Through, Far-End Fault, Auto-MDIX e Loopback
- Per le versioni Managed: Gestibili SNMP, config./controllo; accesso Telnet/SSH, CLI, Web/HTTPS; segnalazione eventi email/Syslog; IPv6
|
|
|
Multimodo |
|
05070312 SMI-100-M2ST2 |
05050202 S-100-M2ST2
|
100BASE-TX to 100BASE-FX 1310nm, 2 Km
|
ST |
05070302 SMI-100-M2SC2 |
05050212 S-100-M2SC2
|
SC |
05070322 SMI-100-M2LC2 |
05050222 S-100-M2LC2
|
LC |
|
|
Monomodo |
|
05070342 SMI-100-S2ST20 |
05050322 S-100-S2ST20
|
|
ST |
05070332 SMI-100-S2SC20 |
05050232 S-100-S2SC20
|
100BASE-TX to 100Base-LX 1310nm, 20 Km |
SC |
05070352 SMI-100-S2LC20 |
05050242 S-100-S2LC20
|
|
LC |
05070362 SMI-100-S2SC40 |
05050252 S-100-S2SC40
|
|
SC |
05070372 SMI-100-S2ST40 |
05050332 S-100-S2ST40
|
100BASE-TX to 100Base-EX 1310nm, 40 Km
|
ST |
05070382 SMI-100-S2LC40 |
05050362 S-100-S2LC40
|
|
LC |
05070392 SMI-100-S2SC80 |
05050372 S-100-S2SC80
|
|
SC |
05070402 SMI-100-S2ST80 |
05050342 S-100-S2ST80 |
100BASE-TX to 100Base-ZX 1550nm, 80 Km |
ST |
05070412 SMI-100-S2LC80 |
05050372 S-100-S2LC80
|
|
LC |
05070422 SMI-100-S2SC120 |
05050312 S-100-S2SC120 |
|
SC |
05070432 SMI-100-S2ST120 |
05050352 S-100-S2ST120
|
100BASE-TX to 100Base-ZX 1550nm, 120 Km |
ST |
05070442 SMI-100-S2LC120 |
05050382 S-100-S2LC120 |
|
LC |
Ethernet 10/100
Rate Converter 10/100 Mbps lato rame e 100 Mbps lato fibra |
P/N Modelli Gestiti |
P/N Modelli Non Gestiti |
Descrizione |
Con. |
|
|
- Distanze fino a 120 km
- Per Fibra multimodo o monomodo
- Connettori SC, LC e ST
- Funzioni avanzate - Link Pass-Through, Far-End Fault, Auto-MDIX e Loopback
|
|
|
Multimodo |
|
05070912 SMI-110-M2ST2 |
05050402 S-110-M2ST2 |
|
ST |
05070902 SMI-110-M2SC2 |
05050412 S-110-M2SC2 |
10/100BASE-TX to 100BASE-FX 1310nm, 2Km
|
SC |
05070922 SMI-110-M2LC2 |
05050422 S-110-M2LC2 |
|
LC |
|
|
Monomodo |
|
05070942 SMI-110-S2ST20 |
05050522 S-110-S2ST20 |
|
ST |
05070932 SMI-110-S2SC20 |
05050412 S-110-S2SC20 |
10/100BASE-TX to 100Base-LX 1310nm, 20Km |
SC |
05070952 SMI-110-S2LC20 |
05050442 S-110-S2LC20 |
|
LC |
05070962 SMI-110-S2SC40 |
05050452 S-110-S2SC40 |
|
SC |
05070972 SMI-110-S2ST40 |
05050532 S-110-S2ST40 |
10/100BASE-TX to 100Base-EX 1310nm, 40Km |
ST |
05070982 SMI-110-S2LC40 |
05050562 S-110-S2LC40 |
|
LC |
05070992 SMI-110-S2SC80 |
05050462 S-110-S2SC80 |
|
SC |
05071002 SMI-110-S2ST80 |
05050542 S-110-S2ST80 |
10/100BASE-TX to 100Base-ZX 1550nm, 80 Km |
ST |
05071012 SMI-110-S2LC80 |
05050572 S-110-S2LC80 |
|
LC |
05071022 SMI-110-S2SC120 |
05050512 S-110-S2SC120 |
|
SC |
05071032 SMI-110-S2ST120 |
05050552 S-110-S2ST120 |
10/100BASE-TX to 100Base-ZX 1550nm (ST), 120 Km |
ST |
05071042 SMI-110-S2LC120 |
05050582 S-110-S2LC120 |
|
LC |
Versioni Temperatura Industriale -40ºC a 75ºC |
|
|
Multimodo |
|
|
05090000 S-110-M2SC2-XT |
|
SC |
|
05090010 S-110-M2ST2-XT |
10/100BASE-TX to 100BASE-FX 1310nm, 2Km |
ST |
|
05090020 S-110-M2LC2-XT |
|
LC |
|
|
Monomodo |
|
|
05090030 S-110-S2SC20-XT |
|
SC |
|
05090040 S-110-S2ST20-XT |
10/100BASE-TX to 100Base-LX 1310nm, 20Km |
ST |
|
05090050 S-110-S2LC20-XT |
|
LC |
|
|
Modelli Single Fiber BIDI |
|
Gigabit
1000 Mbps lato rame e lato fibra |
Modelli Gestiti |
Modelli Non Gestiti |
Descrizione |
Con. |
|
|
- Distanze fino a 120 km
- Per multimodo o monomodo; Connettori SC, LC e ST
- Funzioni avanzate - Link Pass-Through intelligente, Fiber Fault Alert (segnalazione errore fibra), Auto-MDIX e Loopback
- Per le versioni Managed: Gestibili SNMP, config./controllo; accesso Telnet/SSH, CLI, Web/HTTPS; segnalazione eventi email/Syslog; IPv6
|
|
|
Multimodo |
|
05070002 SMI-1000-M2SC05 |
05050002 S-1000-M2SC05 |
|
SC |
05070022 SMI-1000-M2LC05 |
05050012 S-1000-M2LC05 |
1000BASE-T to 1000BASE SX 850nm, 550m
|
LC |
05070012 SMI-1000-M2ST05 |
05050102 S-1000-M2ST05 |
|
ST |
05070492 SMI-1000-M2SC2 |
05040942 S-1000-M2SC2 |
|
SC |
05070502 SMI-1000-M2LC2 |
05040962 S-1000-M2LC2 |
1000BASE-T to 1000BASE LX 1310 nm, 2Km
|
LC |
05070512 SMI-1000-M2ST2 |
05040952 S-1000-M2ST2 |
|
ST |
|
|
Monomodo |
|
05070032 SMI-1000-S2SC10 |
05050032 S-1000-S2SC10 |
|
SC |
05070052 SMI-1000-S2LC10 |
05050022 S-1000-S2LC10 |
1000BASE-T to 1000BASE LX 1310 nm, 10Km
|
LC |
05070042 SMI-1000-S2ST10 |
05050112 S-1000-S2ST10 |
|
ST |
05070062 SMI-1000-S2SC40 |
05050092 S-1000-S2SC40 |
|
SC |
05070082 SMI-1000-S2LC40 |
05050042 S-1000-S2LC40 |
1000BASE-T to 1000BASE EX 1310 nm, 40 Km
|
LC |
05070072 SMI-1000-S2ST40 |
05050122 S-1000-S2ST40 |
|
ST |
05070092 SMI-1000-S2SC70 |
05050052 S-1000-S2SC70 |
|
SC |
05070112 SMI-1000-S2LC70 |
05050062 S-1000-S2LC70 |
1000BASE-T to 1000BASE ZX 1550 nm, 70Km
|
LC |
05070102 SMI-1000-S2ST70 |
05050132 S-1000-S2ST70 |
|
ST |
05070122 SMI-1000-S2SC120 |
05050152 S-1000-S2SC120 |
|
SC |
05070142 SMI-1000-S2LC120 |
05050162 S-1000-S2LC120 |
1000BASE-T to 1000BASE ZX 1550 nm, 120Km
|
LC |
05070132 SMI-1000-S2ST120 |
05050142 S-1000-S2ST120 |
|
ST |
* Mode Conditioning Adapter
- 05059997, MCA 1000-50SC2 - IEEE 802.3z-compliant, consisting of a single-mode fiber permanently coupled off-center to a 50-micron multimode optical fiber with duplex SC connectors at both ends.
- 05059998, MCA1000-62SC2 - Gigabit. IEEE 802.3z-compliant, consisting of a single-mode fiber permanently coupled off-center to a 62.5-micron multimode optical fiber with duplex SC connectors at both ends.
Ethernet 10/100/1000
Rate Converter 10/100/1000 Mbps lato rame, 1Gbps lato fibra |
Modelli Gestiti |
Modelli non Gestiti |
Descrizione |
Con. |
|
|
- Distanze fino a 120 km
- Per multimodo o monomodo; Connettori SC, LC e ST
- Funzioni avanzate - Link Pass-Through intelligente, Fiber Fault Alert (segnalazione errore fibra), Auto-MDIX e Loopback
- Per le versioni Managed: Gestibili SNMP, config./controllo; accesso Telnet/SSH, CLI, Web/HTTPS; segnalazione eventi email/Syslog; IPv6
|
|
|
Multimodo |
|
05070602 SMI-1110-M2SC05 |
05050602 S-1110-M2SC05 |
|
SC |
05070622 SMI-1110-M2LC05 |
05050612 S-1110-M2LC05 |
10/100/1000BASE-T to 1000BASE SX 850nm, 550m
|
LC |
05070612 SMI-1110-M2ST05 |
05050712 S-1110-M2ST05 |
|
ST |
05070522 SMI-1110-M2SC2 |
05040972 S-1110-M2SC2 |
|
SC |
05070542 SMI-1110-M2LC2 |
05040992 S-1110-M2LC2 |
10/100/1000 Base T to 1000BASE LX 1310 nm, 2Km
|
LC |
05070532 SMI-1110-M2ST2 |
05040982 S-1110-M2ST2 |
|
ST |
|
|
Monomodo |
|
05070632 SMI-1110-S2SC10 |
05050632 S-1110-S2SC10 |
10/100/1000 Base T to 1000BASE LX 1310 nm, 10Km
|
SC |
05070652 SMI-1110-S2LC10 |
05050622 S-1110-S2LC10 |
LC |
05070642 SMI-1110-S2ST10 |
05050722 S-1110-S2ST10 |
ST |
05070662 SMI-1110-S2SC40 |
05050692 S-1110-S2SC40 |
|
SC |
05070682 SMI-1110-S2LC40 |
05050642 S-1110-S2LC40 |
10/100/1000BASE-T to 1000BASE EX 1310 nm, 40Km |
LC |
05070672 SMI-1110-S2ST40 |
05050732 S-1110-S2ST40 |
|
ST |
05070692 SMI-1110-S2SC70 |
05050652 S-1110-S2SC70 |
|
SC |
05070712 SMI-1110-S2LC70 |
05050662 S-1110-S2LC70 |
10/100/1000BASE-T to 1000BASE ZX 1550 nm, 70Km |
LC |
05070702 SMI-1110-S2ST70 |
05050742 S-1110-S2ST70 |
|
ST |
05070722 SMI-1110-S2SC120 |
05050762 S-1110-S2SC120 |
|
SC |
05070742 SMI-1110-S2LC120 |
05050772 S-1110-S2LC120 |
10/100/1000BASE-T to 1000BASE ZX 1550 nm, 120Km |
LC |
05070732 SMI-1110-S2ST120 |
05050752 S-1110-S2ST120 |
|
ST |
Versioni Temperatura Industriale -40ºC a 75ºC |
|
|
Multimodo |
|
|
05090670 S-1110-M2SC05-XT |
10/100/1000BASE-T to 1000BASE SX 850nm, 550m |
SC |
|
05090690 S-1110-M2LC05-XT |
LC |
|
05090680 S-1110-M2ST05-XT |
ST |
|
|
Monomodo |
|
|
05090700 S-1110-M2SC10-XT |
10/100/1000 Base T to 1000BASE LX 1310 nm, 10Km |
SC |
|
05090710 S-1110-M2ST10-XT |
ST |
|
05090720 S-1110-M2LC10-XT |
LC |
* Mode Conditioning Adapter
- 05059997, MCA 1000-50SC2 - IEEE 802.3z-compliant, consisting of a single-mode fiber permanently coupled off-center to a 50-micron multimode optical fiber with duplex SC connectors at both ends.
- 05059998, MCA1000-62SC2 - Gigabit. IEEE 802.3z-compliant, consisting of a single-mode fiber permanently coupled off-center to a 62.5-micron multimode optical fiber with duplex SC connectors at both ends.